Kenty PDF

The Pocket Colorimeter II™ has two manuals. The Basic and Full User Manuals can be found below. All Pocket Colorimeter™ II instruments. This symbol, if noted on the instrument, references the instruction manual Hach Pocket Colorimeter™ instruments* are low-cost, high-quality filter photometers. Consult HACH’s Pocket Colorimeter II brochure on ArchiExpo. Page: 1/4.

Author: Kazikazahn Mogami
Country: Guinea-Bissau
Language: English (Spanish)
Genre: History
Published (Last): 14 September 2015
Pages: 349
PDF File Size: 13.3 Mb
ePub File Size: 8.87 Mb
ISBN: 542-7-95939-894-2
Downloads: 51720
Price: Free* [*Free Regsitration Required]
Uploader: Fetilar

You can add Community Subscriptions in the search bar that says “Subscribe to more communities When all the calibration data has been entered, press twice to return to MENU the measurement mode. Place the blank into the cell holder, with the diamond The arrow should indicate the Samples must be Note Deionized water or a reagent blank can be used to zero during the calibration procedure.

Many are based on EPA approved methods. For example, if five points have been entered, three can xolorimeter deleted using this feature. This manual also for: Enter the concentration value and absorbance value of the first data pair S0, A0. Use a TenSette pipet to add 0. At least two data pairs concentration and absorbance are required. Add to My Bench. It’s lightweight and battery operated, suitable for extended field work or quick, on-the-spot process monitoring.

Pocket Colorimeter II – HACH – PDF Catalogs | Documentation | Brochures

Open the catalog to page 3. Adjust sample pH to 6—7. Instrument Operation, continued Battery Installation Figure 1 on page 2—7 provides an exploded view of battery installation. POWER sample the blank. Light emitting diode LED Detector: Used to enter a predetermined calibration curve.

  DESCARCARE DECLARATIA 394 PDF

This initializes zeroes the meter. Page 71 User-Entered Calibration, continued 5. On the basis of strict liability or under any other legal theory, in no event shall Hach Company be liable for any incidental or consequential damages of any kind for breach of warranty or negligence.

Safety Precautions Please read this entire manual before unpacking, setting up, or operating this instrument. Operation is subject to the following two conditions: See Interferences on page 1— Open the catalog to page 2. Each instrument comes in a ready-to-use kit that includes a manual, sample cells, and a sturdy custom carrying case.

International Customers Hach maintains a worldwide network of dealers and distributors. It’s lightweight and battery operated, suitable for extended field work or quick, on-the-spot process monitoring.

Order information | Hach-Lange POCKET Colorimeter II User Manual | Page 4 / 4 | Original mode

Entering a predetermined calibration curve requires at least two data pairs. Summary Of Method Summary of Method Chlorine can be present in water as free chlorine and as combined chlorine.

A tough, impact-resistant shell protects the electronics and optics, while a lanyard keeps the colorimetdr attached to the colorimeter. Repeat this sequence until the S0 concentration value is entered.

  DA VINCIJEV KOD PDF

Determine amount to be added on a separate mL sample, then add the same amount to the sample being tested.

Hach Pocket Colorimeter™ II for Chlorine or Manganese

The instrument has two channels in which measurements can be made. Don’t have an account?

Use the instrument cap cord to secure the cap to the body of the colorimeter and prevent loss of the cap. For order information by E-mail: User-Entered Calibration, continued Table of Contents Safety Precautions Single Parameter go anywhere portable photometer Lightweight and battery operated, suitable for extended field work or quick, on-the-spot process monitoring.

Menu Selections Press the key to access the menu selections. The Pocket Colorimeter II is designed to measure solutions contained in sample cells.

Tightly cover the cell with the instrument cap. Up to 10 standards can be used to determine the calibration. Place the four batteries provided with the instrument in the holder as indicated and replace the battery compartment cover.

The Pocket Colorimeter II is simple enough to use that anyone can obtain reliable results with accuracy comparable to that of a lab instrument.

Call or E-mail techhelp hach.