I have a Carrier 50TJ unit that on start up the 1st stage ices up on the top of the coil but the bottom 3 passes do not get guys checked. If you need to replace the condenser coils in your Carrier 50TJ series unit, Nationwide Coils is here to help. It is no longer necessary to source replacement . Carrier Packaged Unit/RTU Model 50TJ (50TJ) Parts – Shop online or call Fast shipping. Open 7 days a week. day return .

Author: Arakazahn Tozahn
Country: Bahrain
Language: English (Spanish)
Genre: Travel
Published (Last): 25 April 2005
Pages: 252
PDF File Size: 2.38 Mb
ePub File Size: 6.84 Mb
ISBN: 406-9-41426-312-9
Downloads: 99999
Price: Free* [*Free Regsitration Required]
Uploader: Akiktilar

The descriptions and photos on this page are posted by the Seller. General Discussion Pro’s Forum: Getting Pumped for ! But what I found was there was only a dirty coil.

CARRIER 50TJ-020-610QH Air Conditioners – Lot of 6

I had that same problem last year, the unit was 3 years old and carrier wouldn’t give a warranty and the customer was not happy. BoE does not require Sellers to list their machines exclusively with BoE. But the price for the coil ended up being more expensive than a new unit figure that out.

If you have further questions please use the ‘Contact the Seller’ button. If a Seller has sold an Item, BoE will try to assist in locating another unit. Additional Prep Fees May Apply.

  IMAGEMAGICK FLATTEN PDF

Someone had come out saying the coil needed replaced because there was a restriction “in” the system, condensor side. Where were you checking your temps at and Im curious what your pressures were in correllation with the evap and condensor temperatures Join Our Marketplace It’s is fast, free and easy! The price of the new coil is just under the price of a new unit checked on that when i encountered the problem.

Does anybody know anything about these metering devices as it seems to us that there may be a restriction or something causing the bottom of the coil to not get cold. Pulled evap coil on one last week and it was plugged, cut liq line manifold from coil and used tip cleaner and nitrogen to clean put back in unit with good drier and worked good.

Contact the seller X.

Item Carrie Item Description. Submit an Offer at or above Minimum Bid to enter into a negotiation with the Seller. I could only see it being the compressor. BoE does not guarantee their accuracy. Then One Foggy Service Call HVAC-Talk is proudly provided by: BoE recommends that the Buyers inspect Items prior to purchase. The coil wasn’t dirty. Mark Checkbox to add to your watched categories. We’ll submit your offer right away and will let you know as soon as the seller responds.

  HTML IVAN BAYROSS PDF

All Categories All Categories: Results 1 to 13 of Call us at All inspection costs are the responsibility of the Buyer and a refundable deposit is required. The refrigerant side was dirty and they didn’t want worry about any problems so they said just get a new unit.

CARRIER 50TJQH Air – For Sale Used

This is NOT a timed auction. Offer full Price to Buy it Now! All times are GMT Said she had a company come crarier and told her the condenser coil was “restricted”, and needed replaced My guys checked the super heat and it is only 2 degrees,and the charge seems ok. Buyers carrieer responsible for all shipping costs including any skidding or crating charges from the Seller.

So a new unit was only a few hundred dollars more installed because of the crane but now has a new warranty. This item has today. You shouldn’t need a new coil, just the headers with the orifices that come off the header.