Hexagon Obti is the perfect complement to the BLUESTAR forensic line of Blood Detection products. This rapid screening test presumes that a bloodstain is of. 1 Function. HEXAGON OBTI has been designed as a rapid immunological test for the qualitative detection of human hemoglobin in stool. Max-Planck-Ring 21 – D Wiesbaden – Germany. Telefon: +49 0 – Telefax: +49 – eMail: [email protected] s. HEXAGON OBTI.

Author: Zulum Vigul
Country: Mayotte
Language: English (Spanish)
Genre: Love
Published (Last): 6 June 2015
Pages: 345
PDF File Size: 6.46 Mb
ePub File Size: 10.47 Mb
ISBN: 134-8-57671-352-7
Downloads: 58902
Price: Free* [*Free Regsitration Required]
Uploader: Doran

Positive results were obtained with blood from primates gorilla, and of some Mustelidae weasel, European polecat, badger. Studies, reports, user’s manual, and MSDS are available for download in the documentation section. A positive result indicates a hexzgon likelihood for the presence of human blood.

A sample of the presumed human blood trace is transferred into the tube with transport medium.

A positive sample is typically detected within minutes. Choose from 6 tests or 24 tests. Order code HU Each box includes 6 collection tubes and 6 tests.

Box of 6 tests. For all orders, please check first our list of distributors. This helps the investigator to choose to collect or not a sample as evidence. False positives Positive results were obtained with blood from primates gorilla, and of some Mustelidae weasel, badger. As little as red cells are required for a positive result. For the proper interpretation of the results, please read the Hochmeister’s report available in the documentation section.

A positive result indicates a strong likelihood for the presence of human blood.

A lab analysis will later confirm or infirm this presumption. This mixture is added drop by drop to the test.

This helps the investigator to choose to collect or not a sample as evidence. Selected For Comparision Compare Now. Therefore a positive result is not in itself an evidence of the presence of human blood, but hdxagon indicates a high probability of its presence.

  BELDEN 1420A PDF

As little as red cells are required for a positive result. A lab analysis will later confirm or infirm this presumption. For the proper interpretation of the results, please read the Hochmeister’s report available in the documentation section. The immunocomplex migrates to the test zone where it is captured by an immobilized second antibody directed against hHb forming a pink test line to indicate a positive result.

This hxeagon is added drop by drop to the test.

Hexagon Obti Human Blood Test

Follow us on Facebook. The test detects whole blood up to a dilution of 1: A positive sample is typically detected within minutes. Both products are identical in their formula, production site, quality and care given to their production, as stated in the confirmation note by the original design manufacturer Human GmbH. Studies, reports, user’s manual, and MSDS are available for download in the documentation section. Positive results were obtained with blood from primates gorilla, and of some Mustelidae weasel, badger.

As little as red cells are required for a positive result. Buy in bulk and save. Box of 24 tests. This rapid screening test presumes that a bloodstain is of human origin. Order code HU Each box includes 24 collection tubes and 24 tests. A sample of the presumed human blood trace is transferred into the tube with transport medium.

Hexagon OBTI Blood Detection Tests

More information and documentation Studies, reports, user’s manual, and MSDS are available for download in the documentation section. This red control line indicates proper function and correct handling of the test. Order code HU Each box includes 6 collection tubes and 6 tests. Human hemoglobin hHb in the sample reacts with a reagent obyi of red colored particles and monoclonal anti-human Hb antibodies.

  BU TOPRAKLARDAN DNYA MARKAS KAR M PDF

Human hemoglobin hHb in the sample reacts with a reagent consisting of red colored particles and hexagn anti-human Hb antibodies. All prices are in USD.

Hexagon OBTI – 6 tests |

This rapid screening test presumes that a bloodstain is of human origin. Box of 24 tests. See 1 more picture. More information and documentation Studies, reports, user’s manual, and MSDS are available for download in the documentation section.

The immunocomplex migrates to the test zone where it is captured by an immobilized hedagon antibody directed against hHb forming a pink test line to indicate a positive result.

A positive result indicates a strong likelihood for the presence of human blood.

This red control line indicates proper function and correct handling of the test. A lab analysis will later confirm or infirm this presumption. The immunocomplex migrates to the test zone where it is captured by an immobilized second antibody directed against hHb forming a pink test line to indicate a positive result. Human hemoglobin hHb in the sample reacts with a reagent consisting of red colored particles and monoclonal anti-human Hb antibodies. A positive sample is typically detected within minutes.

Order code HU Each box includes 24 collection tubes and 24 tests. A positive result is not in itself an evidence of the presence of human blood but it indicates a high probability of its presence.